  1. Jason,

    I need some electronics advice. I want to feed the single coolant radiator/ a/c condenser fan from two different source, the radiator temp switch and the a/c condenser fan signals. I need two diodes to do that. Can you tell me what kind and spec the diodes should be?

    Best regards,

    John Hewes

    1. Show previous comments  3 more
    2. fjord-tii

      fjord-tii

      Jason,

      Yeah, that’s what I started out with but cannot find a relay with two inputs (e.g., 86 and 86a) and one output (87). All I could find were relays with two outputs (87 and 87a) and a single input (86). Attached is the relay used in the Behr AC system that I don’t have, thought instead using the two diodes, attached.DC3206C0-173B-4DFC-B5AB-90876523DEE9.jpeg

    3. fjord-tii

      fjord-tii

      Jason,

      I also think that’s the way to go. I will add 10A diodes to both leads 5o be safe. Thanks for your consideration.

      - John

    4. JsnPpp

      JsnPpp

      Yes, that would cover you for sure. 

       

      Glad to help! Sounds like you had it already ? 

       

      JasonP

×
×